Space Scripts- 공간의 문장들
A stage designer’s gaze on visually striking cinema. Exploring how space, silence, and structure shape emotion—on screen and on stage.
Oldboy – A Locked Room, A Horizontal Corridor, and a Designed Truth

Stage Setup Guide: Nowon Culture and Arts Center

 

Stage Setup Guide: Nowon Culture and Arts Center – Technical Specs & Safety Points



🎭 Venue Overview


The Nowon Culture and Arts Center Main Hall, located in northern Seoul,
is a medium-sized proscenium theater with a total capacity of 550 seats (358 on the 1st floor, 185 on the 2nd).
Its well-structured stage layout is highly accessible for first-time production teams.

  • Stage Width: 16.2 meters

  • Stage Depth: 12.96 meters

  • Grid Height: 21.34 meters

The space supports full-scale productions and offers generous rigging height for lighting and set installations.


🛠 Stage Floor & Platform Units




The default stage floor is not black, but finished in light-toned wood,
which creates strong light reflections during general lighting setups.
If your production requires a darker or more focused mood, consider using platform units with black foam board (pommex) or floor painting.

"A bright floor reflects more than just light—it diffuses emotional tone."


Platform Unit Dimensions (Fixed Height: 15cm)

TypeDimensions (cm)Quantity
2 × 360 × 9010
2 × 660 × 18010
3 × 390 × 9010
3 × 690 × 18020
4 × 3120 × 9010
4 × 6120 × 18020
6 × 6180 × 18010
Support Blocks30 × 4580
  • Height: All platforms fixed at 15cm

  • Finish Materials: Black pommex available upon request
     ✖️ Carpet is not provided


🚚 Equipment Access & Lift Info




The venue features a truck-accessible rear loading dock with the following specs:

  • Loading Entrance:
     → Height: 4300mm
     → Width: 2800mm
     → Accessible for 3.5-ton trucks

  • Freight Lift:
     → Dimensions: 4.54m × 2.3m
     → Stage level difference: –1270mm
     → Use of ramp or platform recommended for safe transfer

"The door may be wide enough—but can your set rotate inside?"

Make sure to pre-plan your access route and check turning radius carefully for large props or modular walls.


⛑ Fire Curtain Zone & Safety Regulations

The front portion of the stage includes a fully operational fire curtain.
This line must always remain clear of any objects, crew, or set pieces.

"The fire curtain doesn't just exist on paper—it comes down, for real."

Additional Safety Reminders

  • Safety helmets must be worn by all crew during setup

  • Two-person teams are required for ladder and high-access work

  • Only authorized venue staff may operate the lift or trap platforms

  • Maintain a minimum 1-meter clear path on stage at all times


📌 Summary Table

CategoryKey Notes
Stage FloorLight wood finish / high light reflection
PlatformsFixed at 15cm / black pommex available
Loading Entrance3.5-ton truck access / H 4300mm × W 2800mm
Lift4.54 × 2.3m / level difference –1270mm
Fire CurtainMust be kept clear at all times / no exceptions